10kW Hybrid Solar Inverter with Split Phase Output, IP65 & Wifi
10kW Hybrid Solar Inverter | 110V/220V | IP65 Protection
Key features
Safe & Reliable
- Complete functional protection measures
- All input and output interfaces have circuit breakers or isolation switches
Friendly & Flexible
- LCD or touch panel are optional
- Diesel generator connection supported
- Parallel supported
- 4 MPPT trackers
Intelligent & Efficient
- Max charging and discharging current reach up to 250A
- Multiple function modes
- Wifi, GPRS, 4G, APP control
SEND INQUIRY
Back to Product List
Split-Phase Hybrid Inverter for High-Load Solar Systems
Designed for properties that combine solar generation, battery storage, and demanding AC loads, the 10kW hybrid solar inverter manages several power sources through one coordinated platform. It converts photovoltaic DC into pure sine wave AC, directs surplus energy to a compatible 48V battery bank, and can return permitted excess power to the grid. Split-phase 110V/220V output supports mixed-voltage circuits, while the IP65 enclosure helps protect internal components in dusty or moisture-prone service areas.
Pure Sine Wave Conversion and Dual-Voltage AC Output
Stable waveform quality matters when one system supplies compressors, pumps, workshop equipment, refrigeration, office electronics, and other loads with different startup characteristics. The inverter responds to changing demand while maintaining controlled voltage and frequency across supported circuits.
- 10kW rated output for substantial household or light commercial loads
- Pure sine wave power for sensitive electronics and motor-driven equipment
- Split-phase 110V/220V AC output for mixed-voltage distribution
- 48V lithium battery compatibility with configurable charging parameters
- IP65 housing for protection against dust and water exposure
- Grid export capability where local rules and metering permit
- Overload, short-circuit, overtemperature, and voltage protection
The dual-voltage architecture reduces the need for separate conversion equipment when a site runs both 110V and 220V appliances. Installers can organize critical and noncritical circuits around the available output while keeping the overall power layout easier to service. Clear operating modes also allow solar, battery, and grid priorities to reflect the project’s intended use.
48V Battery Charging, Grid Export, and Backup Power Control
Battery charging settings can be matched to the selected lithium battery specification, including charge current, voltage limits, and discharge thresholds. During strong solar production, available power can serve active loads first and charge the battery with the remaining energy. When solar input falls, stored power can support designated circuits before the system draws from the grid.
Grid-connected operation adds another layer of control. Where utility requirements allow export, the 10kW hybrid solar inverter can send permitted surplus generation beyond local consumption. Protection functions monitor current, voltage, temperature, and fault conditions throughout operation, helping the system respond to abnormal events without relying on separate protective devices for every source.
JSDSolar can configure communication settings, battery matching, output voltage, monitoring options, and enclosure details around the electrical requirements of each project. Technical support can also cover wiring layout, load assessment, and operating-mode selection before installation.
Product Detals

Technical Data
| Parameter Category | Specific Parameter Details |
| Technical Data Model | J10KLNA |
| Max. DC Input Power | 15kW |
| Number of MPPT Trackers | 4 |
| MPPT Voltage Range | 120 - 500V |
| Max. DC Voltage | 500V |
| Full-power Operating Voltage Range | 120 - 430V |
| Max. Input Current | 14A |
| Max. Short Circuit Current | 22A |
| Battery Input Data | |
| Nominal Voltage (Vdc) | 51.2V |
| Max. Charging/Discharging Current | 190A/210A |
| Battery Voltage Range | 40 - 60V |
| Battery Type | Lithium-Ion Battery / Lead-Acid Battery |
| Compatibility with Battery Management System | Self-adaptation to BMS |
| AC Output Data (Grid-connected) | |
| Nominal Output Power (Grid-connected) | 10kVA |
| Max. Apparent Power Output (Grid-connected) | 11kVA |
| Output Voltage Range | 110 - 120/220 - 240V split phase, 10, 230 1-phase 208/220 3-phase |
| Output Frequency | 50/60Hz (45 to 54.9Hz / 55 to 65Hz) |
| Nominal AC Current Output (Grid-connected) | 41.7A |
| Max. AC Current Output (Grid-connected) | 45.8A |
| Output Power Factor | 0.8 leading - 0.8 lagging |
| Output THDI | <2% |
| Max. Grid Pass-through Current | 100A |
| AC Output Data (Off-grid) | |
| Nominal Apparent Power Output | 10kVA |
| Max. Apparent Power Output | 10kVA |
| Nominal Output Voltage L-N/L1-L2 | 120/240V |
| Nominal Output Frequency | 60Hz |
| Output THDU | <2% |
| Efficiency | |
| European Efficiency | ≥97.8% |
| Max. Battery to Load Efficiency | ≥97.2% |
| Protection Functions | |
| Over-temperature Detection | YES |
| Arc Fault Detection | YES |
| Islanding Protection | YES |
| Battery Reverse Connection Protection | YES |
| Insulation Resistance Monitoring | YES |
| Residual Current Operated Monitoring Unit | YES |
| Output Over-current Protection | YES |
| Back-up Current Short-circuit Protection | YES |
| Output Over-voltage Protection | YES |
| Output Under-voltage Protection | YES |
| General Data | |
| Operating Temperature Range | -25 - +60°C (+45°C derating) |
| Relative Humidity | 0 - 95% |
| Operating Altitude | 0 - 4000m |
| Ingress Protection | IP65/Type 3R |
| Weight | 48kg |
| Size (Width x Depth x Height) | 450mm x 420mm x 820mm |
| Cooling Method | Natural Convection |
| Noise Emission | <38dB |
| Display | LED |
| Communication with BMS/Meter/EMS | RS485, CAN |
| Supported Communication Interfaces | RS485, WLAN, 4G (optional) |
| Power Consumption | <15W |
| Safety Standards | UL1741SA, UL1699B, CSA 22.2 |
| EMC | FCC Part 15 Class B |
| Grid-connection Standards | IEEE 1547, IEEE 2030.5, Hawaii Rule 14H, Rule 21 Phase I, II, III |
Solar Energy Cases for Different Residential
Common Questions
-
Will Jsdsolar inverter shut down in extreme heat?
-
Our high-quality inverters include thermal protection and cooling systems. Ensure proper ventilation and avoid direct sunlight installation to maintain stable operation in hot climates.
-
How does an inverter handle frequent power surges?
-
Jsdsolar's stable inverters feature surge protection (e.g., 150% overload capacity) and voltage regulation to safeguard connected devices during grid fluctuations or storms.
-
Can saltwater exposure damage the inverter?
-
Opt for inverters with IP65-rated waterproof enclosures and corrosion-resistant materials, especially in coastal areas. Regular cleaning of terminals prevents salt buildup.
-
Will your inverter work with different battery types?
-
Compatible inverters support lithium-ion, lead-acid, and gel batteries. Verify voltage compatibility (typically 24V/48V) and consult specifications before pairing.
-
How often should I maintain my inverter?
-
Bi-annual inspections are recommended: clean vents, check cable integrity, and update firmware. Professional servicing every 2-3 years ensures optimal performance.
Get Free Quote
Our sale team will give full support and price you needed. We are more than happy to answer your questions within 24 hours.
SEND INQUIRY